Ultrasonic level sensor Prosonic FMU30

Brand: Endress+Hauser

Ultrasonic level sensor Prosonic FMU30

Brand: Endress+Hauser

George E. Booth, Endress+Hauser's exclusive USA representative in:
IN Parts of IL KY OH

Fundamental Fundamental

Specs at a Glance

Accuracy:
+/- 3 mm or +/- 0.2 % of set measuring range
Max. measurement distance:
Sensor 1-1/2": 2 m (6.6 ft)
Sensor 2": 3.5 m (11 ft)
Process pressure / max. overpressure limit:
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Process temperature:
-20 °C ... 60 °C
(-4 °F ... 140 °F)
Main wetted parts:
PP/EPDM

Field of application

The Prosonic FMU30 is an ultrasonic level sensor for applications in liquids and bulk solids, such as pump control, level alarms or any two-point control operations. The non-contact ultrasonic measurement minimizes services requirements. With the integrated temperature sensor, temperature dependency is automatically corrected. The optional display with push button shows envelope curves for simple on-site diagnostics and operation.

Key Benefits

  • Non-contact measurement method minimizes service requirements
  • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
  • Graphical display with envelope curve onsite

Specifications

Field of Application

  • Oil exploration and production
  • Polymers
  • Convenience food
  • Concrete, quarry, gravel, sand, asphalt
  • Industrial process water
  • Cement, lime and gypsum

Industry

  • Water, Wastewater & Waste
  • Power & Energy
  • Mining, Minerals & Metals

Target Customer

  • Chemical industry
  • Waste water treatment plants
  • Mining & Minerals industry
  • Metal industry
  • Power & Energy industry

Product Family

  • Prosonic

Continuous / Liquids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire

Accuracy

  • +/- 3 mm or +/- 0,2 % of set measuring range

Ambient temperature

  • -20 °C ... 60 °C
  • (-4 °F ... 140 °F)

Process temperature

  • -20 °C ... 60 °C
  • (- 4°F ... 140 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PP/EPDM

Process connection

  • G / NPT 1 1/2"
  • G / NPT 2"

Blocking distance

  • 1 1/2": 0.25 m (0.8 ft)
  • 2":0.35 m (1.15 ft)

Application

  • Application

Max. measurement distance

  • Max. measurement distance

Communication

  • 4...20 mA

Certificates / Approvals

  • ATEX, CSA C/US, IEC Ex, NEPSI

Options

  • Accessory Enclosed:
  • UNI flange 2" ... 4"

Application limits

  • Application limits

Continuous / Solids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire

Accuracy

  • +/- 3 mm or +/- 0.2 % of set measuring range

Ambient temperature

  • -20 °C ... 60 °C
  • (-4 °F ... 140 °F)

Process temperature

  • -20 °C ... 60 °C
  • (-4 °F ... 140 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PP/EPDM

Process connection

  • G / NPT 1 1/2"
  • G / NPT 2"

Blocking distance

  • Sensor 1 1/2": 0.25 m
  • Sensor 2": 0.35 m

Max. measurement distance

  • Sensor 1-1/2": 2 m (6.6 ft)
  • Sensor 2": 3.5 m (11 ft)

Communication

  • 4...20 mA

Certificates / Approvals

  • ATEX, CSA C/US, IEC Ex, NEPSI

Options

  • Accessory Enclosed:
  • UNI flange 2" ... 4"

Application limits

  • Take notice of range diagram

Documentation

No Videos

show more